To ignite the burners, turn the main gas valve (2) so it is parallel to the gas line (3). Both valves pilot (1) and main (2) are in the ON position. The pilot flame (4) will remain lit throughout the firing cycle. Protect the pilot flame from strong drafts. If it should blow out the temperature sensor will cool down and the gas flow will be cut off to the kiln.

Previous Home Next

kiln015

kiln015.jpg